日本語

  GM-115-EM15

Cleaning agent moisture meter Top model

This product has most of the features needed for moisture measurement.

● Temperature correction / conductivity correction
● Upper / lower limit relay contacts and analog output
● Simple dirt detection ※1
● Digital moisture display after correction(wt%)
● Scale over display(LED lighting)
● Scale over output(NPN open collector)

GM-115-EM13B

  GM-115

Simple cleaning liquid moisture meter With dirt detection function

It measures the water content and conductivity at the same time, and presents monitoring information on the degree of contamination of the liquid (the degree of mixing of flux, sludge, etc.).

● Reasonable price
● Simple dirt detection ※1
● Digital voltage output without temperature correction
※You have to convert the voltage output to a moisture value.
● Analog output
● Scale over display(LED lighting)
● Scale over output(NPN open collector))

※1:Dirt detection:It is effective when dirt is a conductive substance such as flux.
When monitoring the degree of contamination, it is premised that the water content of the cleaning agent is controlled by the output signal so that it is constant.

GM-115

  Features

●Easy to handle

Real-time measurement is possible online.


●Just immerse the sensor in the liquid

Moisture measurement and moisture control can be performed immediately.


●More accurate moisture measurement

Dirt and temperature changes are dealt with by measuring conductivity and temperature and performing correction calculations.


●Enhanced resistance to harsh temperature environments

We customize the moisture meter according to the measurement situation in your factory.

  Application

GM115-Application

Regarding the installation of the sensor

  • You must keep the sensor immersed in the cleaning agent at all times.
  • You must keep the state there is no air bubbles around the sensor because it affects the measurement accuracy.
  • Install in a place where there is not much cleaning dirt.We recommend installing after the cleaning-dirt removal device.
  • You must keep the sludge from sticking inside the electrodes.
  • If the temperature of the cleaning agent changes significantly during measurement, it is recommended to measure with a product that has a temperature compensation function.
  • We recommend that you install the sensor vertically on a sub-tank because it is easier to calibrate and maintenance can be performed even during operation.

Regarding the moisture adjustment

  • Moisture adjustment should be done in the sub tank for optimum mixing with the cleaning agent.
  • If the difference in specific gravity between the cleaning agent and water is large, or if the amount of circulation by the pump is small, excessive water supply may occur.It is recommended to adjust the water content gradually by reducing the flow rate.

  Performance

Actual correction calculation in moisture measurement

The measured value changes depending on the conductivity of the object to be measured. If only the measured value is calculated and presented as the water content, a large error will occur between the presented value and the actual water content.
This product reduces the error by measuring the capacitance and conductivity at the same time and correcting the conductivity.
And since the permittivity depends on the temperature of the object to be measured, the capacitance and temperature are measured by temperature transducer at the same time to correct the temperature too.GM-115 provides the most effective moisture measurement.


●Temperature converter

To correct the temperature, it is necessary to add a temperature converter and a temperature sensor.
Install the temperature sensor near the measurement electrode.


●Calculation display part(Control part)

The moisture value is the calculated value of capacitance, conductivity, and temperature.
You can start using it immediately by just one-point calibration in the field because the reference moisture value is pre-written in the ROM.


●Measurement electrode(Sensor)

The measuring electrode has a simple structure with no mechanical moving parts.
So it is easy to install and has excellent durability.
Since it has a simple structure, it can be manufactured in various shapes.


●Actual example

The measurement data by GM-115 of a certain company's quasi-aqueous cleaning agent is shown in a graph.

113N
113N
113N

If you measure new liquid and 5% sewage without correction, there will be a difference between the two values.

If you correct the conductivity, the error will disappear and the converted values will match.

113N
113N
113N

If you measure 70℃ liquid and 30℃ liquid without correction, there will be a difference between the two values.

If the temperature is corrected, the error will disappear and the converted values will match.

  Standard specifications

Model typeGM-115-EM15GM-115EMC-115OM-13
SpecificationsMethod Capacitance,conductivity,
temperature calculation
Capacitance,conductivity
calculation
Capacitance,conductivity,
temperature calculation
Capacitance,temperature
calculation
Power-supply voltageAC100V±10% 50/60Hz AC100V±10% 50/60Hz
(With power cord)
AC100~240V
50/60Hz
Power consumption30W7W30W
Accuracy ※2±1wt%±0.05wt%
(No air bubbles or dirt)
Moisture value output
(At the measurement range)
DC4~20mA
Resistive load up to450Ω
DC4~20mA
Resistive load up to450Ω
DC0~10V
Resistive load up to5kΩ
DC4~20mA Resistive load up to450Ω
Dirt concentration output (Conductivity)DC 0~10V Resistive load 5kΩ or more×
Operating temperature limitUp to 60℃
(Control unit Up to 40℃)
Up to 60℃ Up to 40℃Up to 60℃
(Control unit Up to 40℃)
Cable length
(Sensor - converter)
Coaxial double shielded cable max3mmax10m
Temperature measurement unitMethodResistor PT-100Ω× Resistor PT-100Ω
Range0~100℃0~100℃
Accuracy±1℃±1℃
Control unitPower-supply voltageAC100~240V±10%
50/60Hz
With any power source
(We have wired)
AC100~240V±10%
50/60Hz
DisplayMoisture:wt%
Temperature:℃
Moisture:wt% Temperature:℃
Capacitance・Conductivity
Moisture:wt%
Temperature:℃
Upper/lower limit alarm contact capacityAC250V-2A,DC30V-2AAC250V-2A、DC30V-2A
ConverterScale over function Orange LED:Capacitance,Red LED:ConductivityRed LED:Conductivity
Scale over outputNPN open collector×
Sensor unitElectrode materialSUS-304,Teflon(PTFE)
Temperature sensorSUS-304×SUS-304
Heat resistant range0~100℃(No condensation or freezing)

※2 In order to make stable measurements with high accuracy, you have to pay attention to the following 7points.

  1. You must set the ambient temperature, degree of dirt, and liquid temperature described in the specifications.
  2. You must not allow air bubbles to enter the cleaning agent inside the sensor.
  3. You must not allow sludge or the like to adhere to the inside of the electrodes.
  4. You must keep the cleaning agent in a uniform emulsified or dissolved state.
  5. You must prevent changes in the components of the cleaning agent due to impurities.
  6. You must not mix conductive substances.
  7. When using multiple units, you must unify the serial numbers.

  External dimensions